Vuln Signal Radar
public-safe defensive signal
CRITICALpublic-safe

CVE-2026-80143

NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...

CVSS
9.4
Severity
CRITICAL
EPSS
0.0151 (73)
KEV
-

Source-published summary

NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...

Possible impact

Source describes admin privilege risk · command injection risk · authenticated boundary. Possible impact: An attacker may gain root or administrative-level privileges on affected systems.

Affected context

Affected product or version requires source confirmation.

Remediation / advisory

Remediation reference present; patch status requires confirmation in the linked advisory.

Why it matters

Source describes admin privilege risk · command injection risk · authenticated boundary. Possible impact: An attacker may gain root or administrative-level privileges on affected systems.; CVSS 9.4 (CRITICAL); EPSS percentile 73; not listed in KEV; Remediation reference present; patch status requires confirmation in the linked advisory; sources: NVD.

What to verify

Confirm affected product/version, vendor advisory, patch or mitigation, and exposure.

Exposure hint

authenticated boundary

Impact tags

admin privilege riskcommand injection riskauthenticated boundary review

Urgency reasons

CVSS CRITICALvendor advisory presentrecent update

Source-derived note

Summary derived from NVD description; unsafe procedural detail is not shown.

Redaction metadata

source summary used
True
fallback summary used
False
unsafe procedural detail present
false
raw source displayed
false
public summary redacted
true

Remediation handoff

Public-safe static handoff for human/Codex remediation planning. Scan, patch, external execution, and auto remediation are disabled.

Safety note

This radar shows source-published defensive context only. Exploit procedures, exploit strings, scanner commands, and auto-remediation are not provided.

Official references