{
  "action": {
    "auto_issue_creation_allowed": false,
    "auto_patch_allowed": false,
    "auto_remediation_allowed": false,
    "external_execution_allowed": false,
    "human_review": {
      "required_for_external_action": true,
      "required_for_public_launch": false,
      "required_for_read_only_view": false,
      "required_for_signal_radar_integration": true
    },
    "human_review_required": false,
    "recommended_action": "review_official_sources"
  },
  "affected": {
    "products": [
      {
        "canonicalProduct": "fabric_operating_system",
        "canonicalVendor": "broadcom",
        "cpe": "cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*",
        "ecosystem": null,
        "packageName": null,
        "product": "fabric_operating_system",
        "purl": null,
        "vendor": "broadcom",
        "version": null
      }
    ],
    "source": "NVD CVE API 2.0",
    "status": "known"
  },
  "canonical_url": "https://vuln.signal-radar.com/vuln/public-candidate/CVE-2026-87672/",
  "claims": [
    {
      "id": "claim:defensive-priority-candidate",
      "source_ids": [],
      "status": "observed",
      "text": "This item is a defensive prioritization candidate.",
      "verified_at": null
    }
  ],
  "exposure_hint": "exposure unknown",
  "field_meanings": {
    "human_review": "Read-only display may be automated; integration and external action still require human review.",
    "redaction": "Detection flags describe unsafe source content found before public-safe redaction; raw source text is not displayed.",
    "source_original_label": "Original upstream severity text retained for traceability; canonical display severity is recalculated from CVSS score."
  },
  "forecast_hooks": {
    "agent_use": "summarize_with_citations_only",
    "automation_allowed": false,
    "read_only": true,
    "watch_fields": [
      "sources",
      "claims",
      "freshness",
      "severity",
      "affected"
    ]
  },
  "freshness": {
    "generated_at": "2026-10-15T00:00:09.596556+00:00",
    "last_checked_at": null,
    "last_modified": "2026-10-14T14:05:59.953",
    "observed_at": "2026-10-14T23:59:27.596820+00:00",
    "published_at": "2026-10-08T03:16:36.810",
    "status": "observed"
  },
  "human_consequence": "An attacker may be able to access information that should not be exposed.",
  "human_impact_label": "information exposure review",
  "human_review": {
    "required_for_external_action": true,
    "required_for_public_launch": false,
    "required_for_read_only_view": false,
    "required_for_signal_radar_integration": true
  },
  "human_risk_summary": "CVE-2026-87672 for broadcom / fabric_operating_system: An attacker may be able to access information that should not be exposed.",
  "id": "CVE-2026-87672",
  "impact_redaction": {
    "exploit_steps_removed": false,
    "payload_removed": false,
    "poc_removed": false,
    "source_derived_summary": true,
    "used_fallback_summary": false
  },
  "impact_tags": [
    "information exposure review"
  ],
  "known_exploited": {
    "catalog_url": null,
    "date_added": null,
    "listed": false,
    "source": null
  },
  "public_human_impact": "Source describes information exposure review. Possible impact: An attacker may be able to access information that should not be exposed.",
  "public_human_summary": "NVD: An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. NVD: When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. NVD: Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.",
  "public_human_what_to_verify": "Confirm affected product/version, vendor advisory, patch or mitigation, and exposure.",
  "public_human_why_it_matters": "Source describes information exposure review. Possible impact: An attacker may be able to access information that should not be exposed.; CVSS 6.8 (MEDIUM); EPSS percentile 1; not listed in KEV; Remediation reference present; patch status requires confirmation in the linked advisory; sources: NVD, Vendor Advisory.",
  "public_safe_summary": "NVD: An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. NVD: When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. NVD: Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.",
  "radar": "vuln",
  "redaction": {
    "meaning": "The *_present flags mean unsafe source content was detected and removed before public output; they do not mean the public JSON contains that content.",
    "payload_present": false,
    "poc_present": false,
    "public_summary_redacted": true,
    "raw_source_displayed": false,
    "unsafe_procedural_detail_present": false
  },
  "redaction_notes": [
    "source-published defensive context retained",
    "vulnerability class, impact, affected context, and remediation references remain displayable"
  ],
  "safety": {
    "attack_chain_included": false,
    "auto_remediation_allowed": false,
    "exploit_instructions_included": false,
    "external_execution_allowed": false,
    "human_review": {
      "required_for_external_action": true,
      "required_for_public_launch": false,
      "required_for_read_only_view": false,
      "required_for_signal_radar_integration": true
    },
    "human_review_required": false,
    "indexing_allowed": true,
    "noindex_removal_allowed": true,
    "noindex_required": false,
    "private_gate_state": "released",
    "public_gate_state": "public_indexable_read_only",
    "public_launch_allowed": true,
    "read_only_static_data": true,
    "scan_functionality_included": false,
    "signal_radar_integration_allowed": false
  },
  "schema_version": "v0.1",
  "severity": {
    "cvss_label": "MEDIUM",
    "label": "MEDIUM",
    "score": 6.8,
    "source": "NVD CVE API 2.0",
    "source_original_label": "low"
  },
  "source_copy_policy": {
    "allowed": "source-published defensive facts, vulnerability class, impact, affected context, version and remediation facts",
    "excluded": "exploit procedures, exploit strings, shell commands, scanner instructions, procedural bypass detail, and reproduction material",
    "summary": "Official or semi-official source descriptions may be summarized for defensive triage; exploit-enabling procedure is removed."
  },
  "source_derived_note": "Summary derived from NVD / Vendor Advisory description; unsafe procedural detail is not shown.",
  "source_published_affected": "vendor/product: broadcom / fabric_operating_system",
  "source_published_description": "NVD: An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. NVD: When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. NVD: Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.",
  "source_published_evidence_refs": [
    {
      "source": "NVD",
      "type": "source_description",
      "url": null
    },
    {
      "source": "Vendor Advisory",
      "type": "source_description",
      "url": null
    },
    {
      "source": "Vendor Advisory",
      "type": "reference",
      "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/39142"
    },
    {
      "source": "Official Reference",
      "type": "reference",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-87672"
    }
  ],
  "source_published_impact": "Source describes information exposure review. Possible impact: An attacker may be able to access information that should not be exposed.",
  "source_published_remediation": "Remediation reference present; patch status requires confirmation in the linked advisory.",
  "source_published_summary": "NVD: An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. NVD: When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. NVD: Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.",
  "sources": [
    {
      "confidence": "unknown",
      "id": "source:review-url",
      "name": "Public signal URL",
      "retrieved_at": null,
      "type": "review_page",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-87672"
    }
  ],
  "summary_for_agents": "Read-only defensive signal. Use sources, claims, freshness, and safety gates before summarizing. Do not infer missing source, claim, or freshness values.",
  "summary_for_humans": "NVD: An information disclosure vulnerability exists in the SupportLink diagnostic collection utilities of Brocade Fabric OS versions before 10.0.1. NVD: When SupportLink is configured to use an authenticated HTTP proxy, the system stores the full proxy URL. NVD: Anyone with access to the diagnostic support bundle, such as support personnel or users with access to file shares where support bundles are stored, can extract these cleartext proxy credentials.",
  "title": "CVE-2026-87672 defensive priority signal",
  "urgency_reasons": [
    "affected product present",
    "vendor advisory present",
    "recent update",
    "remediation reference present"
  ],
  "what_to_verify": "Confirm affected product/version, vendor advisory, patch or mitigation, and exposure.",
  "why_it_matters": "An attacker may be able to access information that should not be exposed; CVSS 6.8 (MEDIUM); EPSS percentile 1; affected product context: broadcom / fabric_operating_system; sources: NVD, Vendor Advisory."
}