{
  "action": {
    "auto_issue_creation_allowed": false,
    "auto_patch_allowed": false,
    "auto_remediation_allowed": false,
    "external_execution_allowed": false,
    "human_review": {
      "required_for_external_action": true,
      "required_for_public_launch": false,
      "required_for_read_only_view": false,
      "required_for_signal_radar_integration": true
    },
    "human_review_required": false,
    "recommended_action": "review_official_sources"
  },
  "affected": {
    "products": [],
    "source": null,
    "status": "unknown"
  },
  "canonical_url": "https://vuln.signal-radar.com/vuln/public-candidate/CVE-2026-80144/",
  "claims": [
    {
      "id": "claim:defensive-priority-candidate",
      "source_ids": [],
      "status": "observed",
      "text": "This item is a defensive prioritization candidate.",
      "verified_at": null
    }
  ],
  "exposure_hint": "authenticated boundary",
  "field_meanings": {
    "human_review": "Read-only display may be automated; integration and external action still require human review.",
    "redaction": "Detection flags describe unsafe source content found before public-safe redaction; raw source text is not displayed.",
    "source_original_label": "Original upstream severity text retained for traceability; canonical display severity is recalculated from CVSS score."
  },
  "forecast_hooks": {
    "agent_use": "summarize_with_citations_only",
    "automation_allowed": false,
    "read_only": true,
    "watch_fields": [
      "sources",
      "claims",
      "freshness",
      "severity",
      "affected"
    ]
  },
  "freshness": {
    "generated_at": "2026-09-29T16:01:40.551491+00:00",
    "last_checked_at": null,
    "last_modified": "2026-09-24T19:17:17.183",
    "observed_at": "2026-09-29T16:00:53.853295+00:00",
    "published_at": "2026-09-22T16:17:59.303",
    "status": "observed"
  },
  "human_consequence": "An attacker may gain root or administrative-level privileges on affected systems.",
  "human_impact_label": "admin privilege risk · command injection risk · authenticated boundary",
  "human_review": {
    "required_for_external_action": true,
    "required_for_public_launch": false,
    "required_for_read_only_view": false,
    "required_for_signal_radar_integration": true
  },
  "human_risk_summary": "CVE-2026-80144: An attacker may gain root or administrative-level privileges on affected systems.",
  "id": "CVE-2026-80144",
  "impact_redaction": {
    "exploit_steps_removed": false,
    "payload_removed": false,
    "poc_removed": false,
    "source_derived_summary": true,
    "used_fallback_summary": false
  },
  "impact_tags": [
    "admin privilege risk",
    "command injection risk",
    "authenticated boundary review"
  ],
  "known_exploited": {
    "catalog_url": null,
    "date_added": null,
    "listed": false,
    "source": null
  },
  "public_human_impact": "Source describes admin privilege risk · command injection risk · authenticated boundary. Possible impact: An attacker may gain root or administrative-level privileges on affected systems.",
  "public_human_summary": "NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...",
  "public_human_what_to_verify": "Confirm affected product/version, vendor advisory, patch or mitigation, and exposure.",
  "public_human_why_it_matters": "Source describes admin privilege risk · command injection risk · authenticated boundary. Possible impact: An attacker may gain root or administrative-level privileges on affected systems.; CVSS 9.4 (CRITICAL); EPSS percentile 73; not listed in KEV; Remediation reference present; patch status requires confirmation in the linked advisory; sources: NVD.",
  "public_safe_summary": "NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...",
  "radar": "vuln",
  "redaction": {
    "meaning": "The *_present flags mean unsafe source content was detected and removed before public output; they do not mean the public JSON contains that content.",
    "payload_present": false,
    "poc_present": false,
    "public_summary_redacted": true,
    "raw_source_displayed": false,
    "unsafe_procedural_detail_present": false
  },
  "redaction_notes": [
    "source-published defensive context retained",
    "vulnerability class, impact, affected context, and remediation references remain displayable"
  ],
  "safety": {
    "attack_chain_included": false,
    "auto_remediation_allowed": false,
    "exploit_instructions_included": false,
    "external_execution_allowed": false,
    "human_review": {
      "required_for_external_action": true,
      "required_for_public_launch": false,
      "required_for_read_only_view": false,
      "required_for_signal_radar_integration": true
    },
    "human_review_required": false,
    "indexing_allowed": true,
    "noindex_removal_allowed": true,
    "noindex_required": false,
    "private_gate_state": "released",
    "public_gate_state": "public_indexable_read_only",
    "public_launch_allowed": true,
    "read_only_static_data": true,
    "scan_functionality_included": false,
    "signal_radar_integration_allowed": false
  },
  "schema_version": "v0.1",
  "severity": {
    "cvss_label": "CRITICAL",
    "label": "CRITICAL",
    "score": 9.4,
    "source": "NVD CVE API 2.0",
    "source_original_label": "medium"
  },
  "source_copy_policy": {
    "allowed": "source-published defensive facts, vulnerability class, impact, affected context, version and remediation facts",
    "excluded": "exploit procedures, exploit strings, shell commands, scanner instructions, procedural bypass detail, and reproduction material",
    "summary": "Official or semi-official source descriptions may be summarized for defensive triage; exploit-enabling procedure is removed."
  },
  "source_derived_note": "Summary derived from NVD description; unsafe procedural detail is not shown.",
  "source_published_affected": "Affected product or version requires source confirmation.",
  "source_published_description": "NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...",
  "source_published_evidence_refs": [
    {
      "source": "NVD",
      "type": "source_description",
      "url": null
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://revrb.net/2026/09/21/revrb-lantern.html"
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://ts.lantronix.com/ftp/SLC9000/9.7.0.2R1/"
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://ts.lantronix.com/ftp/emg/EMG_7500/9.7.0.1R2/"
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://ts.lantronix.com/ftp/emg/EMG_8500/9.7.0.1R2/"
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://ts.lantronix.com/ftp/slc8000/9.7.0.2R1/"
    },
    {
      "source": "Reference",
      "type": "reference",
      "url": "https://www.vulncheck.com/advisories/lantronix-autonomous-out-of-band-devices-cli-command-injection-via-mfc-eeprom-write"
    },
    {
      "source": "Official Reference",
      "type": "reference",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-80144"
    }
  ],
  "source_published_impact": "Source describes admin privilege risk · command injection risk · authenticated boundary. Possible impact: An attacker may gain root or administrative-level privileges on affected systems.",
  "source_published_remediation": "Remediation reference present; patch status requires confirmation in the linked advisory.",
  "source_published_summary": "NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...",
  "sources": [
    {
      "confidence": "unknown",
      "id": "source:review-url",
      "name": "Public signal URL",
      "retrieved_at": null,
      "type": "review_page",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2026-80144"
    }
  ],
  "summary_for_agents": "Read-only defensive signal. Use sources, claims, freshness, and safety gates before summarizing. Do not infer missing source, claim, or freshness values.",
  "summary_for_humans": "NVD: Lantronix SLC8000/SLC9000 before firmware v9.7.0.2, EMG8500/EMG7500 before firmware v9.7.0.1, and all firmware versions of SLB882/SLCx-03/SLCx-02 contain a command injection vulnerability that allows authenticated attackers to execute arbitrary shell commands... NVD: Attackers can authenticate as any user to the terminal or CLI interface and inject malicious commands through the unsanitized parameter to achieve complete loss of confidentiality, integrity, and availability on the affected device and potentially impact...",
  "title": "CVE-2026-80144 defensive priority signal",
  "urgency_reasons": [
    "CVSS CRITICAL",
    "vendor advisory present",
    "recent update"
  ],
  "what_to_verify": "Confirm affected product/version, vendor advisory, patch or mitigation, and exposure.",
  "why_it_matters": "An attacker may gain root or administrative-level privileges on affected systems; CVSS 9.4 (CRITICAL); EPSS percentile 73; sources: NVD."
}